1500 GPD / 250LPH Commercial & Industrial water reverse osmosis system ro plant
This RO system is one of our company's best-selling products, with a flow rate of 250lph, and the price is very competitive in the market. The 250lph RO system is small in size and light in weight. It is especially suitable for use in homes, schools, villas, hotels, etc. where direct drinking is required and the machine is fully automated. If the water level is high, the machine will stop automatically.
The machine can be easily operated without special technical knowledge. The normal voltage of the RO system is generally 220V/50Hz (the voltage can also be configured according to different countries). PH range of raw water is 3-10, Water Pressure is the 3-5 bar and TDS of source water is about 100-1000ppm. Application of raw water is Tap water, city water, underground water, well water,borehole water, river water etc.
RO system is suitable for various use scenarios around the world, Even if the using voltage or water pressure doesn't meet the requirement of the machine, Our special and Professional team to cooperate with you to solve the solution. The 250 LPH RO system is suitable for a large family and villa for 20 peoples. In addition, it is widely used in GCC Countries (Saudi Arabia, Oman, Qater, UAE) Southeast Asia (Philippines, Indonesia, Malaysia), South America (Peru, Ecuador, Colombia) and Africa (Africa, Angola, Nigeria). Our brand of the water treatment system is a leadership water treatment company in southeast Asia, South America and Africa regions. There are also exclusive agents in South Africa to cooperate with us for 10 years to expand our business in the Africa regions. Generally, the number of products ordered in a container for that consumers have an important agenda on the issue to drink the water safely. We have introduced 250 LPH RO equipment's to meet the water requirements.
★ RO water treatment Plant is a compact, easy installation.
★ RO plant produces as per CE standard and main parts accessories have obtained SGS certification.
★ Price is very attractive.
★ Control box: An easy-to-understand controller that can view the TDS value of the produced water from the controller.
★ RO membrane: RO system the most important accessory for the RO membrane, it can remove perfectly over 99% ions. The biggest feature is that it can remove heavy metals and bacteria. After the RO process, the TDS can reach 20-40ppm or less. However, the quality of drinking water is accepted and recognized by International standards. RO system has two important concepts, one is the recovery rate and the other is the salt rejection rate. The recovery rate refers to the percentage of water in the RO membrane system which converted into water or permeates. We use the most advanced RO membrane technology and the recovery rate is approximately 45%-50%. The RO membrane system is designed based on the preset water inflow. Depending on the quality of water, the concentrate valve on the concentrated water line can be adjusted and set for recovery. Depending on the quality and production of water requirements to maximize the maximum production of water. The salt rejection rate refers to the percentage of the total soluble impurity concentration removed from the system influent through the reverse osmosis membrane. We use well-known brands of RO membranes such as Voltron and Dow therefor the salt rejection rate can reach 96%-99% and the high purity water can be consumed properly and directly. No need to boil with a kettle, don’t need to save time and electricity.
★ RO membrane housing: It is made of 304 stainless steel and the quality is perfect for guaranteed.
★ High-pressure Pump: Our famous brand CNP pump or Grundfos pump allows the best use of the machine and extend the life of the machine and also enhance reliability.
★ Precision filter: Before passing through the RO membrane, we will use the precision filter to remove the sediment which larger than 10 microns, so that the life of the protective RO membrane is longer and it is not going to block easily.
Step 1: Prepare the machine before running then the RO system is connected to the raw water pipe to transport the water to the machine and connect the local power supply on the machine to install PP filter elements on the precision filter and RO membrane to the RO membrane housing. Finally, pure water is to prepare to store in a water tank.
Step 2: Supervision work in machine operation.
In operation: After completing the above preparations, you can press the start button. During normal operation, the wastewater valve can adjust the recovery rate to achieve the desired water quality. After the processing of water production should check the TDS value from the control panel.
Step 3: Document recording after the machine is running. After running: Record the running water production, operating pressure, and water quality. Meanwhile, the specific data will be shown in the flow meter, pressure gauge, and conductivity controller.